Airflow Direction; Package Contents - Avaya VSP 4450GSX-PWR+ Installing

Virtual services platform
Hide thumbs Also See for VSP 4450GSX-PWR+:
Table of Contents

Advertisement

Installing the Avaya VSP 4000 4450GSX series
Environmental requirement
Operating and Storage Humidity
Maximum Operating Altitude
Altitude
Storage Altitude
Acoustic Noise
Miscellaneous Operating
Considerations
Warning:
To avoid bodily injury from hazardous electrical shock and current, never remove the top of the
device. No user-serviceable components are inside. For a translation of this statement, see
Translations of safety messages

Airflow direction

Airflow direction in the VSP 4450GSX-PWR+ is from left to right (as viewed from the front). Cool air
enters the chassis through an air inlet at the left of the chassis, which cools the device. Warm air
exits through the exhaust at the right.

Package contents

The following describes the components that are provided with the packaging of each switch. If any
components are missing, contact the switch vendor.
1. Avaya Virtual Services Platform 4000 4450GSX-PWR+ or 4450GSX-DC switch with one
power supply installed. VSP 4450GSX-DC model comes installed with a DC power supply.
November 2016
Avaya Virtual Services Platform 4000 models
0 to 95 percent noncondensing
3,048m (10 000 feet) above sea level
0 to 3,048m (0 to 10,000ft) above sea level
0 to 12,192m (0 to 40,000ft) above sea level
Less than or equal to 45 db at 35°C and less than or equal to 57 db at
50°C. The temperature is allowed to have ±3.5°C deviation around the
threshold of 35C, (measurement methods based on ISO 7779).
• No heat sources such as hot air vents or direct sunlight near the
switch.
• No sources of severe electromagnetic interference near the switch.
• No excessive dust in the environment.
• An adequate power source is within 6 feet (1.83 meters) of the switch.
One 15-amp circuit is required for each power supply.
• At least 2 inches (5.08 centimeters) of clearance on each side of the
switch unit for ventilation.
• Adequate clearance at the front and rear of the switch for access to
cables.
on page 38.
Installing Avaya Virtual Services Platform 4450GSX-PWR+ Switch
Comments on this document? infodev@avaya.com