Huawei eA660 Series User Manual page 53

Cpe
Hide thumbs Also See for eA660 Series:
Table of Contents

Advertisement

eA660 Series CPE
User Guide
Table 3-6 Hardware installation check of the eA660
No.
1
2
3
When checking the cable connections of the eA660, check the items listed in Table 3-7 in
order.
Table 3-7 Cable connection check of the eA660
No.
1
2
3
4
Step 2 Perform the power-on check, as shown in Figure 3-49.
Issue 06 (2019-04-03)
Check Item
The installation position must strictly comply with the design
drawings, meet the installation space requirements, and reserve space
for maintenance.
When the eA660 is mounted on a metal utility pole, the fixture must
be firmly installed, and the CPE must be attached.
When the eA660 is mounted on the wall, the installation hole on the
fixture must be aligned with the one on the expansion bolt. In addition,
the fixture must be tightly and firmly attached to the wall and must not
wobble when you shake it.
Check Item
No cable is short-circuited or inversely connected.
The bare wires and lugs of the connecting terminal must be tightly
wrapped with insulation tapes. Cooper wires must not be exposed.
Power cables or PGND cables with connectors are not used.
The connector of the PoE network cable must be appropriately
connected.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.