Huawei eA660 Series User Manual page 13

Cpe
Hide thumbs Also See for eA660 Series:
Table of Contents

Advertisement

eA660 Series CPE
User Guide
It is recommended that you change the password for connections between the CPE and central office
TR-069 management equipment at regular intervals.
Ensure that the settings for the CPE and central office TR-069 management equipment are the same.
Otherwise, the CPE cannot be managed by the central office TR-069 management equipment.
Issue 06 (2019-04-03)
The account used for connections between the CPE and central office TR-069
management equipment is managed by personnel in the central office. The default
account name and passwords are admin and Changeme123, respectively.
You can also change the password for connections between the CPE and central
office TR-069 management equipment. A password must meet the following rules:
The length of the password: 6 to 15 characters.
A password contains at least three types of characters of the following:
Lowercase letter
Uppercase letter
Digit
Special characters, including the space character and the following:
`~!@#$%^&*()-_=+\|[{}];:'",<.>/?
The password cannot be the user name or the reverse order of the user name.
A password cannot contain more than two consecutive characters that are the
same (for example, 111 is not allowed.)
MD5 digest authentication is used for connections between the CPE and central
office TR-069 management equipment, and the authentication complies with TR-069
Amendment 4.
When TR-069 network management is enabled, each registration of the CPE will
generate about 70 KB of data traffic, each periodic reporting will generate about 20 KB
of data traffic, and the data traffic generated by each update depends on the update
package size. An update package is generally smaller than 100 MB, and updates are
triggered by the central office management equipment.
When TR-069 network management is enabled, the CPE regularly connects to the central
office management equipment, and the connection cycle complies with TR-069
Amendment 4.
Digest authentication prevents the account and password used for connections between
the CPE and central office TR-069 management equipment from being cracked. The
number of attempts is five. After five attempt failures, wait five minutes and receive new
connection authentication requests.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1 Overview
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ea660-118Ea660-123Ea660-135Ea660-137Ea660-160

Table of Contents