EXCELL PRECISION CO., LTD.
2-2-5 Tare Function
1. When the weight of the container is unknown (
Place the container on the platter, after stable and press
value returns to zero and net indication (Net) is on.
Place goods into the container, then the indicator shows the net weight of goods.
Clear tare value
When removing the container and goods, the display shows the negative weight
value of the container. Then press
returns to zero and net indication (Net) is on.
Recall tare value
Press
Multiple tare operation Users can continuously increase or decrease the tare value
by pressing the
The total tare value (tare value + pre-set tare value) can equal the full capacity of the
indicator.
2. When the weight of the container is known (
Press
Use
the procedures, the net indication
Place goods into the container, then the indicator shows the net weight of goods.
Clear pretare value
Press
When the indicator returns to zero, net indication (Net) and pretare indication ""
are off.
Recall pretare value
Press
In Tare mode, the Preset tare function is disabled.
The indicators with two weighing ranges can NOT pre-set the tare value larger than the
first weighing range. For example: a 30 kg indicator is set by two weighing ranges. The
first range is 0 to 15 kg, and the second range is 15 to 30 kg. The pre-set tare value can
not be larger than 15 kg.
02029010
key the display shows tare value
then
key.
key and the display shows
and
keys to input weight value of the container. After finishing
then
key, and then press
key the display shows pretare value
then
)
key to clear tare value. The indicator
)
.
and pretare indication "" is on.
Net
(
)
12
key, the weight
.
key to clear pretare value.
ZSME300000363