Section 2: Safety Precautions - ESAB ARCAIR SLICE Series Safety And Operating Instructions Manual

Exothermic cutting equipment
Table of Contents

Advertisement

SLICE EXOTHERMIC CUTTING EQUIPMENT

SECTION 2: SAFETY PRECAUTIONS

WARNING
!
SERIOUS INJURY OR DEATH may result if welding and cutting equipment
is not properly installed, used, and maintained. Misuse of this equipment
and other unsafe practices can be hazardous. The operator, supervisor, and
helper must read and understand the following safety warnings and instruc-
tions before installing or using any welding or cutting equipment, and be
aware of the dangers of the welding or cutting process. Training and proper
supervision are important for a safe work place. Keep these instructions for
future use. Additional recommended safety and operating information is refer-
enced in each section.
WARNING
!
This product contains chemicals, including lead, or otherwise produces
chemicals known to the State of California to cause cancer, birth defects
and other reproductive harm. Wash hands after handling.
ELECTRIC SHOCK CAN CAUSE INJURY OR DEATH
The purchaser is responsible for the safe installation, operation, and use of all products
purchased, including compliance with all applicable ISO standards and local codes in
the country of use. Do not service or repair equipment with power on. Do not operate
equipment with protective insulators or covers removed. Service or repair to equipment
must be done by qualified and/or trained personnel only.
Do not contact electrically live parts. Always wear dry welding gloves that are in good condition.
Aluminized, protective clothing can become part of the electrical path. Keep oxygen cylinders, chains,
wires, ropes, cranes, and hoists away from any part of the electrical path. All ground connections must
be checked periodically to determine if they are mechanically strong, and electrically adequate for the
required current. When engaged in AC welding/cutting under wet conditions or where perspiration
is a factor, the use of automatic controls for reducing the no load voltage is recommended to reduce
shock hazards. Accidental contact must be prevented when using open circuit voltage exceeding 80
volts AC, or 100 volts DC by adequate insulation or other means. When welding is to be suspended for
any length of time, such as during lunch or overnight, all electrode holders and electrodes should be
removed from the electrode holder and the power supply should be turned off to prevent accidental
contact. Keep MIG Guns, electrode holders, TIG torches, Plasma torches, and electrodes away from
moisture and water. See safety and operating references 1, 2, and 8.
SMOKE, FUMES, AND GASES CAN BE DANGEROUS TO YOUR HEALTH
Ventilation must be adequate to remove smoke, fumes, and gases during operation to
protect operators and others in the area. Vapors of chlorinated solvents can form the
toxic gas "Phosgene" when exposed to ultraviolet radiation from an electric arc. All
solvents, degreasers, and potential sources of these vapors must be removed from the
operating area. Use air-supplied respirators if ventilation is not adequate to remove all
fumes and gases. Oxygen supports, and vigorously accelerates fire and should never be used for
ventilation. See safety and operating references 1, 2, 3, and 4.
2
89250840

Advertisement

Table of Contents
loading

Table of Contents