12.
Remove the two (2) side panels by undoing the top and
bottom screw in each.
13.
Put the suction cups on the inner glass.
14.
Loosen the four (4) 1/4 turn fasteners and remove the
glass retainer.
15.
Tilt the glass towards yourself and lift it out. Be aware
that if any soot is present on the glass, it may stain
carpet or furnishings. Set the glass aside and use a
fireplace glass cleaner to clean the glass.
66
MAINTENANCE AND SERVICE
Checking Manifold Pressures
Both propane and natural gas valves have a built-in pressure
regulator in the gas valve. Natural gas models will have a
manifold pressure of approximately 3.5-in w.c. (.871 kPa)
at the valve outlet with the inlet pressure to the valve from
a minimum of 4.5-in w.c. (1.120 kPa) for the purpose of
input adjustment to a maximum of 14.0-in w.c. (3.484
kPa). Propane gas models will have a manifold pressure
approximately 10.0-in w.c. (2.49 kPa) at the valve outlet with
the inlet pressure to the valve from a minimum of 10.8-in w.c.
(2.68 kPa) for the purpose of input adjustment to a maximum
of 14.0-in w.c. (3.484 kPa).
If one of the procedures results in pressures in excess of 1/2 psig
(14-in w.c./3.5 kPa) on the fireplace gas valve, it will result in a
hazardous condition.
GAS VALVE
CAUTION
INLET
PRESSURE
TAP
OUTLET
PRESSURE
TAP