TSS-Sub1200
subwoofer
INFINITY TSS-1200 250W Powered Sub/ Plate Amp
LINE VOLTAGE
US 120vac/60Hz
EU 230vac/50-60Hz
Parameter
Amp Section
Type (Class AB, D, other)
Load Impedance (speaker)
Rated Output Power (120VAC
Rated Output Power (230VAC
AVG RMS Dynamic Power
AVG RMS Dynamic Power
THD @ Rated Power
THD @ 1 Watt
DC Offset
Damping factor
Input Sensitivity
Input Frequency
L or R input
L or R input
Gain L & R
Signal to Noise
SNR-A-Weighted
SNR-unweighted
SNR rel. 1W-unweighted
Residual Noise Floor
Input Impedance
Line Input (L, R)
Filters
LP filter 4th order
HP Filter 2nd order
LFE Low pass 2nd order
Notch filter (Friend circuit)
Limiter
THD at Max. Output Power
Features
Volume pot Taper (lin/log)
Phase switch
LP Filter defeat switch (LFE-
Normal)
Input Configuration
Line In (L,R) & LFE
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
ATO Input test frequency
ATO Level LFE Input
ATO Turn-on time
Auto Mute/ Turn-OFF Time
Power on Delay time
Transients/Pops
ATO Transient
Yes/No
Hi/Lo Line
Nom.
Yes
108-132
Yes
207-264
QA Test
Specification
Unit
Limits
D
n/a
5.6
Ohms
150
Watts
150
Watts
250
Watts
250
Watts
0.5
%
0.1
%
10
mV-DC
>50
DF
35
Hz
16.8
mVrms
±2dB
16.8
mVrms
±2dB
±2dB
140
90
dBA
85
dBr
65
dBr
1
mVrms(max)
> 10K
ohms
50-150
Hz
± 10
Fixed
200>LP<1K
Hz
n/a
n/a
functional Maximum Output Power
--
LOG
--
functional
0-180
deg
functional
YES
functional
YES
--
functional
YES
functional
50
Hz
functional
2
mV
functional
5
ms
functional
15
minutes
3
sec.
5
mV-peak
Unit
120
Vrms
230
Vrms
Conditions
n/a
n/a
Nominal
125
125
225
5.6 Ohms
189
4 Ohms
1
22K filter
0.3
22K filter
30
Amplifier output
20
Measured at amplifier board
35
Nominal Freq.
To 1 Watt, Ap Zo=600 Ohms
To 1 Watt , Ap Zo=600 Ohms
43 dB
85
relative to rated power
85
relative to rated power
65
relative to 1W Output
Volume @max, w/ A/P Swept
Bandpass Measurement (Line
1.5
freq.+ harmonics) (BW=20 Khz)
n/a
Nominal
2nd Order variable and 2nd order fix
LFE input driven only
F=61 Hz, Q=3.607, Av=-8.62dB
"
"
Amp connected and AC on, then
input signal applied
T before muting, after line or
18
speaker level signal is removed
4
AC Power Applied
n/a
@ Speaker Output
2
Notes
Normal Operation
Normal operation, MOMS required
Notes
Domestic version only 120 VAC-60 Hz
EU Version only
230 VAC-50 Hz
Average RMS power, 3/20 Cycles 50 Hz, Driven
6dB above its input sensitivity sensitivity
Reference
Measured at the amplifier board. 120 Watts @
50 Hz, THD must be less tan 0.1%
Single input driven, Normal mode
Single input driven, LFE mode switch ON
Reference
A-Weighting filter
22K filter
22K filter
Line level inputs must be terminated using
1KOHM
See AP curves 2nd order variable + 2nd order
fix-24 db/Octave
Maximum THD as a result of limiting.
A Taper
Disables LP filter, intended for LFE
Dual RCA jack
Maximum acceptable level.
Auto turn of time (T) must be 5 > T < 18