ENGLISH
, CLEANING
Pull the rotary shave face off the hair pocket (Fig. 1 and 2).
Tap out excess hair shavings from the hair pocket (Fig. 3). Hair clippings can
also be washed out of the hair pocket and or shave face by rinsing these
under the tap.
Once dry, snap the shave face back onto the hair pocket (Fig. 4).
, CLEANING TRIMMER
Lubricate the teeth of the trimmer every six months with a drop of sewing
machine oil.

BATTERY REMOVAL

The battery must be removed from the appliance before it is scrapped.
The appliance must be disconnected from the supply mains when removing
the battery.
Run shaver until the motor stops.
Remove the head from the shaver (pull the head up and off).
Using a small screwdriver, pry the 'collar' off of the top of the handle.
Using a small screwdriver, pry the front cover from the body.
Remove three screws located on front of shaver.
Using a small screw driver, pry up the newly unsecured inner housing to
expose the battery.
Pry battery free from circuit board.
Dispose of battery properly.
H ENVIRONMENTAL PROTECTION
To avoid environmental and health problems due to hazardous
substances in electrical and electronic goods, appliances marked with
this symbol must not be disposed of with unsorted municipal waste,
but recovered, reused or recycled.