installation planning
EN
2.3
minimum clearance to combustibles
WARNING
!
•
Do not install into any area having less than 7 feet (2.1m) (ceiling to appliance bottom, excluding hearth height).
PARALLEL &
CORNER
Sidewall (A)
Sidewall to fl ue (B)
Backwall (C)
Backwall to fl ue (D)
Corner (E)
Ceiling (F)
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with
NFPA 211 or CAN/CSA-B365.
note:
*
Only applicable with the use of low clearance combustion kit RCHS20. See "accessories" section for more
information.
2.4
alcove installation
Your appliance may be installed using a listed
double wall connector (such as Security DL6 in
Canada, the Simpson Duravent Plus DVL in the
USA, or an equivalent double wall connector) into
an alcove having a depth of no more than 4 feet
(1.2m) and a height of at least 6'3" (1.8m x 76mm).
The minimum clearances are as shown.
PARALLEL & CORNER
Ceiling (G)
Sidewall (H)
Sidewall to fl ue (I)
Backwall (J)
Backwall to fl ue (K)
10
W415-2796 / B / 12.19.19
BACK WALL
D
C
A
B
SINGLE WALL
CONNECTOR
13" (33cm)
22 7/8" (58.1cm)
11 1/2" (29.2cm)
15" (38.1cm)
11" (27.9cm)
SINGLE WALL CONNECTOR
BACK WALL
E
E
DOUBLE WALL
CONNECTOR
12" (30.5cm)
21 1/2" (54.6cm)
9 1/2" (24.1cm)
12 1/2" (31.8cm)
84" (213.4cm)
G
F
ALCOVE
DOUBLE WALL CONNECTOR
N/A
F
DOUBLE WALL
CONNECTOR +
DOUBLE BACK SHIELD
AND TOP SHIELD *
5 1/2" (14cm)
8 1/2" (21.6cm)
7" (17.8cm)
K
J
A
B
19"
48" (122cm)
(48.3cm)
H
MAX
I
28
/
"
7
ALCOVE
8
(733.4mm)
75" (190.5cm)
19" (48.3cm)
28 7/8" (73.3cm)
12 1/2" (31.8cm)
16" (40.6cm)