Configuration; Language; Date And Time; Vbus - Caleffi solar iSolar DL3 Manual

Table of Contents

Advertisement

5.5

Configuration

In the Configuration menu, different adjustments
can be made.
Î In order to access the menu, press button 3 for
approx. 3 s.
Menu structure
The menu consists of the following sub-menus:

• Language

• Time

• VBus

• Sensors

• Logging
• Network
• Erase
• Version x.x
Î In order to access the adjustment mode of a sub-
menu, select the desired sub-menu by pressing
buttons 1 and 2, and confirm with button 3.
5.5.1 Language
In the Language sub-menu, the menu language can
be selected.
Î Select the desired language by pressing buttons
1 and 2.
Î Briefly press button 3 to confirm the selection.
Î In order to get back to the Configuration menu,
select Back and confirm by pressing button 3.

5.5.2 Date and time

In the Time sub-menu, the date and time can be ad-
justed.
Î To adjust the date, select the menu item Date in
the Time sub-menu.
Î Adjust the year by pressing buttons 1 and 2, and
confirm with button 3.
Now the month is displayed, too. As soon as it has
been adjusted and confirmed, the day appears as well.
Î Adjust and confirm the current month and day as
described above.
Î To adjust the time, select the menu item Time in
the Time sub-menu.
Î Adjust the hours by pressing buttons 1 and 2, and
confirm with button 3.
Î Adjust the minutes by pressing buttons 1 and 2,
and confirm with button 3.
5.5.3 VBus
In the VBus sub-menu, the monitoring of the VBus
connections can be activated.
Î Select the desired VBus
connection by pressing
®
buttons 1 and 2, and confirm with button 3.
Î To activate the monitoring of the VBus
tion, select Yes. To deactivate the monitoring of
the VBus
®
connection, select No.
If an error occurs in a VBus
connection, the operating
®
control LED flashes and the message VBus (1 ... 6)
no signal appears on the display.
5.5.4 Sensors
In the Sensors sub-menu, the sensor type and an off-
set can be adjusted for each sensor input.
Sensor type
For the sensor inputs S1 ... S3, the following sensor
types are available:
• None
• Pt1000
• Pt500
• Impulse
• KTY
The selection Offset is not available when
the sensor type Impulse has been selected.
In order to adjust the sensor type, proceed as follows:
Î Select the desired sensor by pressing buttons 1
and 2, and confirm with button 3.
Î Select the menu item Type and confirm by press-
ing button 3.
Î Select the right sensor type and confirm by press-
ing button 3.
If the sensor type Impulse has been selected, the
®
impulse rate can be adjusted. In order to adjust the
impulse rate, proceed as follows:
Î Select the desired sensor by pressing buttons 1
and 2, and confirm with button 3.
connec-
®
Î In the corresponding sensor menu, select the
menu item Vol./Imp.
Î Adjust the desired value by pressing buttons 1
and 2, and confirm with button 3.
Sensor offset
In order to adjust an offset for the sensor inputs S1 ... S3,
proceed as follows:
Î Select the desired sensor by pressing buttons 1
and 2, and confirm with button 3.
Î Select the menu item Offset and confirm by
pressing button 3.
Î Adjust the desired value by pressing buttons 1
and 2, and confirm with button 3.
9