If the current loop interface is used, the type can be
adjusted. The following types are available:
• None
• 0 - 20 mA
• 4 - 20 mA
• Si-420TC
In order to adjust the type, proceed as follows:
Î Select the menu item Current loop by pressing
buttons 1 and 2, and confirm with button 3.
Î Select the Type sub-menu.
Î Select the right type and confirm by pressing but-
ton 3.
If an error occurs in a sensor connection, the op-
erating control LED flashes and the message Input
(1 ... 4) no signal appears on the display.

5.5.5 Logging

In the Logging sub-menu, the following adjustments
can be made:
• Interval
• Logging type
• SD card (only if an SD card has been inserted into
the SD card slot)
When Interval has been selected, the logging interval
can be adjusted. In order to adjust the interval, pro-
ceed as follows:
Î Select the number of minutes by pressing buttons
1 and 2, and confirm with button 3.
Î Select the number of seconds by pressing buttons
1 and 2, and confirm with button 3.
In the menu item Log. type, one of the following log-
ging types can be selected:
• linear
• cyclic
10
When linear is adjusted in the Logging type ad-
justment channel, data logging will stop if the capacity
limit is reached. If cyclic is adjusted, the oldest data
logged into the internal memory will be overwritten
as soon as the capacity limit is reached.
When Log. type has been selected, the logging type
can be adjusted. In order to adjust the logging type,
proceed as follows:
Î Select the desired logging type by pressing but-
tons 1 and 2, and confirm with button 3.
In the menu item SD card, the following adjustments
can be made:
• Backup
• Format card
• Update
When Backup has been activated, the data logged
over the previous day will be copied onto the SD card
at midnight (00:00), using the VBus
data remain in the internal memory as well.
When Format card has been selected, the SD card
will be formatted. In order to format the SD card, pro-
ceed as follows:
Î Select the menu item Format card by pressing
buttons 1 and 2, and confirm with button 3.
Î To format the card, select Yes and confirm by
pressing button 3.
During the formatting process, the message Please
wait... is indicated. When formatting has been com-
pleted, the message Successful! appears. Press any
key to leave the menu item.
When an SD card with a firmware update is inserted,
the enquiry Update? is indicated on the display.
Î To run the update, select Yes and confirm by
pressing button 3 (see chap. 6 Firmware up-
date with SD card, page 13).
If no firmware update is found on the memory card,
the query Copy data? appears.
Î To copy the data logged in the internal memory,
select Yes and confirm by pressing button 3; to
cancel the function, select No and confirm by
pressing button 3.

5.5.6 Network

In the Network sub-menu, the following adjustments
can be made:
• VBus.net
• LAN
VBus.net can be used to access the iSolar DL3 over
the Internet without adjusting the router . In order to
activate VBus.net, proceed as follows:
Î Select VBus.net by pressing buttons 1 and 2, and
confirm with button 3.
Î Select the menu item Log in and confirm by
data format. The
®
pressing button 3.
Î To register the iSolar DL3 for VBus.net, select
Yes and confirm by pressing button 3.
Î Select the menu item Log-in code by pressing
buttons 1 and 2, and confirm with button 3.
The iSolar DL3 generates a 6-digit code and registers
its address with the server. To access the data, a user
account at VBus.net is required. In order to register
with the server, proceed as follows:
Î Open a user account at www.vbus.net.
Î Choose a user name and password.
Î Enter the code generated by the DL3 in the user
account.
In the LAN sub-menu, the following adjustments can
be made for accessing the Datalogger over LAN:
• Auto configuration
• Address
• Mask
• Recover IP