4.2

Electrical connection

Note
Connecting the device to the power sup-
ply must always be the last step of the in-
stallation!
Carry out the connection of the Datalogger
(pos. 1) to other modules in the order de-
scribed below:
Î Connect the data cable (VBus
controller (pos. 12) and the DL3 (pos. 1). If neces-
sary, extend the cable using the terminal block
included (pos. 7) and a common two-wire cable.
Î Connect the mains adapter (pos. 2 / 3) to the DL3
and to a mains socket.
Î For a direct connection to a router or a PC, con-
nect the Datalogger to a router or a PC using
the network cable (included with the DL3, pos. 5).
Power supply is carried out via an external mains
adapter. The supply voltage of the mains adapter must
be 100 ... 240 V~ (50 ... 60 Hz).
The mains adapter and a VBus
cable are included
®
with the DL3.
1
12
12
4
4
4.3
Connecting the VBus
cable
®
The iSolar DL3 is connected to one or several con-
trollers via VBus
cables. The corresponding terminal
®
allocation is described in the controller manual.
The VBus
cable can be extended using the terminal
®
block included and a common two-wire cable.
6
VBus
connection at the terminals:
®
1 / 2 = VBus
®
connection 1 (slave)
3 / 4 = VBus
connection 2 (slave)
®
5 / 6 = VBus
connection 3 (slave)
®
7 / 8 = VBus
connection 4 (slave)
®
9 / 10 = VBus
®
11 / 12 = VBus
, pos. 4) to the
®
To the VBus
connections 1 ... 6, master devices (con-
®
trollers) can be connected.
4.4

Connecting the sensors

Connect the temperature sensors to the following
terminals with either polarity:
/ S1 ... S3 = Temperature sensors S1 to S3
Connect the sensor using a 0(4)-20 mA signal as spec-
ified by the manufacturer to the following terminals:
/ CL = Current loop interface 0(4)-20 mA
CALEFFI
NORTH AMERICA, Inc.
Milwaukee,WI 53208
VBus 1
VBus 2 VBus 3 VBus 4
1
2
3
connection 5 (slave)
®
connection 6 (slave)
Master/Slave
VBus 5
VBus 6
4
5
6
7
8
9
10
11 12
4.5

Connecting the network cable

The iSolar DL3 can be connected to a computer or a
router by using a network cable (CAT5e, RJ45).
Î Connect the network cable included to the net-
work adapter of the computer or the router.
ATTENTION!
VBus
network malfunction!
®
Separating the device from the pow-
er supply while the VBus
nected can lead to a VBus
malfunction!
Î Separate VBus
before separating the device
from the power supply!
12V
1A max.
LAN
USB
is still con-
®
network
®
connections
®
IP 20
S1
S2
S3

Advertisement

Table of Contents
loading

Table of Contents