Clean flue gas collecting channel

Open the firebox door.
Loosen the two hex head screws and remove the lower front panel.
Remove the cover plate by opening the two outer hexagon screw.
Vacuum clean the combustion residues from the flue gas collection channel.
Install the removed parts in reverse order.
Note
Your stove may suck in false air via incorrectly sealed cleaning covers; this
air may lead to incomplete combustion in the fire trough and thus piling up of
pellets. DANGER of FIRE!
To ensure the proper operation of your pellet stove, replace any defect
(porous, frayed) seals after cleaning and maintenance.

Cleaning the flue pipes

(annually)
Remove the flue pipes. Inspect and clean the chimney connection. Brush off any
soot and dust deposits in the fire and in the flue pipes and vacuum.
Note
# 8
Accumulated fly ash in the flue gas channels may impair the performance of
the stove and pose a safety risk.

Bearings

(annually)
All built-in bearings (pellet screw) should be checked. Clean or replace bearings
depending on condition.

Checking door seal

(annually)
# 10
The condition of the seals at doors and glass should be checked at least once
a year. Repair or replace seals depending on condition.
Note
Only intact seals ensure your stove works perfectly!