INSTALLATION

1. Mark on the wall for appropriate position for fixing bracket,
and drill four holes with diameter of 12mm and depth of
70-76mm with churn drilling as shown in illustration, and fill
in the holes with bulge screw and tighten the screw to set
the fixing bracket.
Note: Ensure the fixing bracket to remain level.
Put the tank onto the fixing bracket as shown in the right
figure and adjust the tank to level . Then tighten screws with
hex-head key. Note: it is a must to keep the tank level.
Connect the inlet hose with tank inlet pipe. (Note: it is
necessary to keep the inlet valve closed at this step.)
1206284-T01-A
1.
(
Level
Tank
Loosen
Tighten
Medium Allen Key
Screw
-3-
12mm
70-76mm
O
Gasket
Spring
)
Connecting Pipe
Water Pipe
Bulge Screw
Fixing Bracket
Nut

Advertisement

loading

This manual is also suitable for:

Ratio k-6283t