TROUBLE SHOOTING PROCEDURES
TROUBLE SHOOTING PROCEDURES
Symptoms
No water fills in via inlet
valve
No drainage when
pressing the heavy and
slight drainage button
Too high or too low water
level
Leak of the toilet and
squat
1206284-T01-A
Probable Causes
The inlet valve is closed
Floating box of inlet valve is blocked by tank wall
Floating box of inlet valve is block by waste
Wrong installation of adjustable board
Control pole is too long
Water level of the inlet valve is not appropriate
Control pole is too short
Inappropriate adjustment of the overflow pipe
Open inlet valve (refer to page 7)
Adjust floating box to appropriate position
Wash the floating box with clean water
Reset (refer to page 7)
Adjust the control pole to appropriate
position
Readjust water level (refer to page 8)
Adjust the control pole to appropriate
position
Adjust the overflow pipe to appropriate
position
-10-

Recommended Action

(
7 )
(
7 )
(
8 )