Rheem Guardian PowerVent Training Manual page 50

Electronic spark to pilot gas (fvir) water heaters
Hide thumbs Also See for Guardian PowerVent:
Table of Contents

Advertisement

Guardian PowerVent Training Manual
Error 14
Indications
The self-diagnostic test found a problem
with the Flammable Vapor Sensor. (This is
not a flammable vapor event. It may be
caused by disconnecting the FV sensor
Molex, or the FV sensor itself. This
includes both short and open electrical
connections.)
Troubleshooting
1. Check all FV sensor wiring harness connections; and the connections to the back of the
sensor.
2. Cycle power to the water heater off for 10 seconds and then back on.
3. If no wiring problems are found, the Flammable Vapor Sensor must be checked.
a. Disconnect the FV sensor Molex and measure the resistance of the sensor
between the two black wires 2 and 3. If the resistance is less than 9k OHMS or
greater than 45k OHMS, then replace the sensor.
b. If the FV sensor is between 9K and 45K and the code will not clear by recycling
power, replace the INTELLI-VENT control.
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
______________________________________________________________________________
Display
SVC900; Rev 1
Page 49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents