Observe And Obey; Before Starting Installation - Genie Lift Guard GR-12 Operator's Manual Supplement

Contact alarm
Hide thumbs Also See for Lift Guard GR-12:
Table of Contents

Advertisement

Operator's Manual Supplement
Introduction
Introduction

Observe and Obey:

This procedure shall be completed by a person
authorized to install the Contact Alarm.
Immediately tag and remove from service a
damaged or malfunctioning machine.
Repair any machine damage or malfunction
before operating the machine.

Before Starting Installation:

Read, understand and obey the safety rules
and operating instructions in the appropriate
operator's manual.
Be sure that all necessary tools and parts are
available and ready for use.
Read this procedure completely and adhere to
the instructions. Attempting shortcuts may
produce hazardous conditions.
6
Attention:
The Lift Guard™ Contact Alarm can only be
installed on machines with the "Proportional Lift"
control system.
It is not compatible with "2 Speed Lift" control
systems.
Refer to the illustrations to determine which control
system is on the machine.
236360 B
1256709 B
Lift Guard™ Contact Alarm
First Edition • First Printing
=
+
-
=
+
-
237127 B
1
2
3
4
2 Speed Lift
=
-
+
1256711 B
Proportional Lift
Part No. 1293402GT
=
+
-
=
+
-