Page 1
Operator's Manual Supplement Lift Guard Contact Alarm ™ ™ ™ ™ ™ First Edition First Printing Part No. 1288739GT...
Page 3
Note: These installation instructions only apply to continue to raise or drive the machine. The to the Genie models listed below: audible alarm and beacons will deactivate when the red Emergency Stop button is pushed in to the GS-1530, GS-1532, GS-1930, GS-1932, GS-2032, off position.
Operator's Manual Supplement First Edition • First Printing Introduction Pre-operation Inspection Contact Alarm Safety Read, understand and obey all warnings and Be sure that the operator’s, safety manual, instructions provided with the contact alarm. responsibilities manual and any necessary Do not exceed the rated platform capacity.
First Edition • First Printing Operator's Manual Supplement Introduction Function Test Note: Perform this procedure from the platform controls in an area free of obstructions. Activate platform up. Move and hold the contact alarm in any direction. Platform up function stops, the beacons flash and the alarm sounds.
Page 6
Operator's Manual Supplement First Edition • First Printing Operating Instructions Operati ng Instr ucti ons Operating Instructions Contact alarm activated, beacon lights flash and an audible alarm sounds. Lift and drive functions will not operate from the platform controls. Note: The potential hazard must be acknowledged by the operator to continue operating the machine.
First Edition • First Printing Operator's Manual Supplement Installation Instructions Installation Ins tructi ons Attention: The Lift Guard ™ Contact Alarm can only be installed on machines with the "Proportional Lift" control system. It is not compatible with "2 Speed Lift" control systems.
Installation Instructions Tools Required: Contents of Kit 1288736GT 3/8 inch wrench GS-1530 / GS-1532 7/16 inch wrench Description Genie part Qty. number 3/8 inch socket Cable tie, 7.375 inch / 19 cm 6578GT 7/16 inch socket Button cable tie, 14.75 inch / 37,5 cm...
Page 9
First Edition • First Printing Operator's Manual Supplement Installation Instructions Contents of Kit 1288738GT Contents of Kit 1289294GT GS-2032 GS-3232 Description Genie part Qty. Description Genie part Qty. number number Cable tie, 7.375 inch / 19 cm 6578GT Cable tie, 7.375 inch / 19 cm 6578GT Button cable tie, 14.75 inch / 37,5 cm...
Page 10
Operator's Manual Supplement First Edition • First Printing Installation Instructions Contents of Kit 1289421GT Contents of Kit 1289422GT GS-2646 GS-3246 Description Genie part Qty. Description Genie part Qty. number number Cable tie, 7.375 inch / 19 cm 6578GT Cable tie, 7.375 inch / 19 cm 6578GT Button cable tie, 14.75 inch / 37,5 cm...
Page 11
First Edition • First Printing Operator's Manual Supplement Installation Instructions Contents of Kit 1289295GT GS-4047 Description Genie part Qty. number Cable tie, 7.375 inch / 19 cm 6578GT Button cable tie, 14.75 inch / 37,5 cm 56361GT Cable tie mount, 6.5 inch / 16,5 cm...
Page 12
13 Connect the black wire of the ESTOP splice Raise the platform 7 to 8 feet / 2.1 to 2.4 m. harness to connector J1 pin 11. Genie part number 1288573GT. Lift the safety arm, move it to the center of the scissor arm and rotate down to a vertical position.
Page 13
33 Route the harness under the platform towards the non-steer of the machine. Secure the harness to the cable guide using button cable ties. Do not tighten the cable ties at this. Genie part number 56361GT. Part No. 1288739GT Lift Guard™ Contact Alarm...
Page 14
Torque to 136 in the cable guide at the non-steer end of the in-lbs / 15,5 Nm. machine with the 45 inch link cable. Genie part number 1288574GT. 35 Gently pull the harness towards the non-steer end of the machine.
Page 15
First Edition • First Printing Operator's Manual Supplement Installation Instructions GS-30 and GS-32 models GS-46 and GS-47 models Part No. 1288739GT Lift Guard™ Contact Alarm...
Page 16
Operator's Manual Supplement First Edition • First Printing Installation Instructions Lift Guard™ Contact Alarm Part No. 1288739GT...
First Edition • First Printing Operator's Manual Supplement Software Update Softwar e U pdate Press the ground control scroll down button. Machines with a control system software revision of "P" or higher do not require a software upgrade. Result: The GCON LCD will show the software revision and hour meter information.
Page 18
Operator's Manual Supplement First Edition • First Printing Software Update Firmware Site Download Activating or Deactivating the Contact Alarm Note: Access to the internet is required to perform this procedure. Note: The contact alarm must be activated in the options menu for the machine to function properly Click on the Hyperlink below or open an when it has been installed on the machine.
Page 19
First Edition • First Printing Operator's Manual Supplement Software Update Pull out the red Emergency Stop button to the on position at the ground controls. Result: The ground controls LCD display will show the following: Use the ground control menu buttons to select machine Options.