Qs3 (Other Data On The Panel) - Pioneer PDP-5010FD Service Manual

Plasma display system
Hide thumbs Also See for PDP-5010FD:
Table of Contents

Advertisement

5

9.3.3 QS3 (OTHER DATA ON THE PANEL)

The command QS3 is for acquiring data on operational information of the panel.
Command
Effective Operation
Format
Modes
[QS3]
All operations
Data Arrangement
ECO
1
SERIAL
2
HOUR METER
3
BACKUP HR METER
4
PON COUNTER
5
TEMP1 acquisition (Temperature value)
6
TEMP0 acquisition (Temperature value)
7
MaxTEMP acquisition (Temperature value)
8
Reserved
9
CS
5
6
Function
To acquire data on operations of the panel Return data: 3 (ECO) + 58 (DATA) + 2 (CS) = 63 Byte
Data
Output Example
Length
3 byte
15 byte
- - - - - - - - - - - - - - -
8 byte
00000000
8 byte
00000000
8 byte
00000000
5 byte
+25.0 (*1)
5 byte
+25.0 (*1)
5 byte
+75.0 (*1)
4 byte
2 byte
PDP-5010FD
6
7
Remarks
QS3
Note
(*1) : Centigrade scale
∗∗∗∗
FB
7
8
A
B
C
D
E
F
157