Pioneer PDP-5010FD Service Manual page 142

Plasma display system
Hide thumbs Also See for PDP-5010FD:
Table of Contents

Advertisement

1
A
DELAY ADJUSTMENT OF THE CONTROL SIGNAL (SUS-D)
1 Measure the pulse width of the SUS-D signal.
2 Check the pulse width of the SUS-D input signal (gate terminal of Q2111).
Adjust the variable control so that the pulse width of the SUS-D input signal (gate terminal of Q2111) becomes the
same pulse width ± 5 nsec as the SUS-D signal.
Note: • Be sure to set the Drive to OFF for adjustment.
• For details on measuring points of waveform, see the figure below.
B
SUS-D signal
(input to the DRIVE Assy)
C
D
E
F
142
1
2
50 % of the crest value
50 % of the crest value
SUS-D signal
(input to the gate terminal of Q2111)
SUS-D pulse width: Tsus - Dg
Adjust so that "Tsus - Dg = Tsus - D ± 5 nsec," using the variable
control shown in the table below:
Assy
VR
Y DRIVE Assy
VR2001
2
3
SUS-D pulse width
Tsus - D
50 % of the crest value
SUS-D pulse width
Tsus - Dg
PDP-5010FD
3
4
50 % of the crest value
4

Hide quick links: