Wire the Switchplate

9
The TracVision system requires an 11-16 VDC power input. A
quick-tripping circuit breaker should be installed between the
switchplate and vehicle power. Circuit overload protection
should be rated for 5 amps. If vehicle power fluctuates widely or
is noisy, a 12 VDC 5-amp AC/DC power supply should be
installed (KVH Part # 19-0402 or equivalent).
1. Disconnect vehicle power by removing the
appropriate vehicle fuse. Test the circuit to ensure
that no power is present.
2. Connect the antenna's data/power cable to the
switchplate's data/power connector and lock in
place.
Data/Power
Switchplate Connections
3. Connect the receiver ground wire(s) to the
switchplate's ground terminal, as shown above.
4. Connect the switchplate to vehicle power and
ground, as shown above.
54-0359 Rev. A
+12 VDC – Vehicle Power
Ground
Receiver Ground
Wire
Before wiring the switchplate, be
sure to disconnect vehicle power by
removing the appropriate vehicle
fuse. Test the circuit to ensure that
no power is present.