Camera Address = 1 × bit 1 Status + 2 x bit 2 Status + 4 × bit 3 Status + 8 × bit 4
* bit Status: On = 1, Off = 0
ex) Camera Address 228 = 1 × 0 (Off) + 2 × 0 (Off) + 4 × 1 (On) + 8 × 0 (Off) + 16 × 0
Set up the protocol and bit rate to match the controllers settings.
(2) SW2 (bit 1 - 2) Protocol
Protocol
TOSHIBA-P
TOSHIBA-D
Reserve1
Reserve2
(3) SW2 (bit3 - 4) Bit Rate
Protocol
1200bps
2400bps
4800bps
9600bps
(Dome base switch:S301)
This is RS422 termination switch located near the BNC connector.
In daisy chain operation system, the farthest dome from the controller is turned ON.
For example, when the controller is connected with three dome cameras in the direct mode,
the only furthest dome camera from a controller is turned ON. The other dome camera is
turned OFF. (It is OFF at the time of shipment.)
ON and OFF are as in a figure.
Status + 16 × bit 5 Status +32 × bit 6 Status + 64 × bit 7
Status + 128 × bit 8 Status
(Off) + 32 × 1 (On) + 64 × 1 (On) + 128 × 1 (On)
= 4 + 32+ 64 + 128 + 228 → Off/Off/On/Off/Off/On/On/On
bit1
bit2
Off
Off
On
Off
Off
On
On
On
bit3
bit4
Off
Off
On
Off
Off
On
On
On
S301
ON
OFF
- 33 -
POWER
TERMINAL
BNC Connector