Viessmann Vitopend 100-W Installation And Service Instructions Manual page 64

Table of Contents

Advertisement

Parameter
Main parameter level
Standby mode
Symbols
Flashing
Constant
Parameter level 1
Calling up parameter level 1:
1. Hold down MODE and
neously for approx. 5 s.
■ "SEt" and
■ "PL:1" is shown on the additional
display.
is shown in the upper display
area
Emissions test mode
Parameter Possible change
"P01"
"OFF" Test mode switch-
"On"
With test mode switched
on, use
tween upper and lower
heating output.
Filling and venting function
Parameter Possible change
"P02"
"OFF" Function switched
"On"
64
(cont.)
Main display
"SEt"
simulta-
flash.
ed off
Test mode switch-
ed on
/
to change be-
off
Function switched
on
Additional display
2. Press MODE.
■ "P01" is shown on the main dis-
play.
appears.
3. Use
/
to select the parameter.
4. OK to confirm
Main display
With test mode
switched on:
■ Temperature
in °C
Main display
With test mode
switched on:
■ "Air"
Additional display
With test mode
switched on:
"LO" For lower
heating out-
put
"HI" For upper
heating out-
put
Additional display
With test mode
switched on:
■ Remaining time
in min