Viessmann Vitopend 100-W Installation And Service Instructions Manual page 28

Table of Contents

Advertisement

Installation sequence
Electrical connections
Connection OpenTherm accessories
X7
1
2
3
B
1
2
3
4
OT
A
A OpenTherm accessories
B Terminals on the control unit
Connecting system to equipotential bonding of the building
Danger
The absence of system compo-
nent earthing can lead to seri-
ous injury from electric current if
an electrical fault occurs.
28
(cont.)
4
Note
Observe parameter "P07", see
page 66.
Recommended connecting cable
■ 2-core cable for low voltage
The appliance and pipework
(especially the gas line) must be
connected to the equipotential
bonding of the building.

Advertisement

Table of Contents
loading

Table of Contents