120 V power supply
Use a flexible cable with the following characteristics:
● UL approval
● CE marking
● Type SJT with three conductors
● At least 18 AWG (0.75 mm
● Maximum 4.5 m length
● Parallel grounded safety plug 15 A, min. 125 V
230 V power supply
Use a flexible cable with the following characteristics:
● UL approval
● CE marking
● Type SJT with three conductors
● At least 18 AWG (0.75 mm
● Maximum 4.5 m length
● Tandem grounded safety plug 15 A, min. 250 V
Procedure
• Plug the connector of the supplied power
supply cable into the AC power supply
connector of the device.
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
Operating Instructions, 07/2016, A5E31298376-AF
) conductor cross-section
2
) conductor cross-section
2
Installing and connecting the device
3.4 Connecting the device
57