7.5 Technical specifications
Pulse-shaped interference
The following table shows the electromagnetic compatibility of modules with regard to pulse-
shaped interference. This requires the device to meet the specifications and directives for
electrical installation.
Pulse-shaped interference
Electrostatic discharge
in accordance with IEC 61000-4-2
Bursts
(high-speed transient interference)
in accordance with IEC 61000-4-4
High-power surge pulses in accordance with IEC 61000-4-5, external protective circuit required
(refer to S7-300 PLC, Installation, chapter "Lightning and overvoltage protection").
Asymmetrical coupling
Symmetrical coupling
The following lightning protection element was used during the testing of the Industrial Flat Panel:
1
Dehn BVT AVD 24" (Order No. 918 422)
Sinusoidal interference
The following table shows the EMC behavior of the modules with respect to sinusoidal
interference. This requires the HMI device to meet the specifications and directives for
electrical installation.
Sinusoidal interference
HF radiation
(electromagnetic fields)
according to IEC 61000-4-3
HF power applied to lines
and line shields according
IEC 61000-4-6
104
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
Test voltage
Air discharge: 8 kV
Contact discharge: 6 kV
Contact discharge: 4 kV
2 kV power supply cable
2 kV signal cable, > 30 m
1 kV signal cable, < 30 m
2 kV power supply cable
DC voltage with protective elements
2 kV signal/data cable, > 30 m,
with protective elements as required
1 kV power supply cable
DC voltage with protective elements
1 kV signal cable, > 30 m,
with protective elements as required
Test values
80% amplitude modulation at 1 kHz
with 10 V/m in the range of 80 MHz to 1 GHz
with 3 V/m in the range 1.4 GHz to 2 GHz
with 1 V/m the range 2 GHz to 2.7 GHz
Test voltage 10 V, with 80%
amplitude modulation of 1 KHz in the range of
150 KHz to 80 MHz
Operating Instructions, 07/2016, A5E31298376-AF
Degree of severity
3
2
3
3
1
1
3
1
1
Degree of severity
3
3

Hide quick links: