Installing and connecting the device
3.3 Mounting the PRO device
Note
Liability disclaimer
The device is mounted to a pedestal or a support arm via the mechanical interface with
screws. Siemens AG assumes no liability for the consequences of incorrect installation.
Warranty at risk
If you do not install the HMI device in accordance with the specifications in these operating
instructions, the warranty for the device is voided.
• Always install the device according to these operating instructions.
• If the seal on the backplane cover is damaged, it can be repaired. For a repair scenario,
following the instructions in the section "Spare parts and repairs (Page 76)".
IP65 degree of protection and Enclosure Type 4X / 12 (indoor use only) at risk
If there are no seals on the mechanical interfaces or if they are damaged, IP65 degree of
protection and Enclosure Type 4X / 12 (indoor use only) is at risk. Check the condition and
proper seating of the seals.
NOTICE
Damaging the seal when opening
If the device has not been opened for a long time, the backplane cover or terminal
compartment cover may stick to the seal of the enclosure. Opening the device with
excessive force or with tools will destroy the seal. Spray and water jets as well as
penetrating substances can then damage the device.
Open the terminal compartment cover gently, without too much pressure.
See also
System components for PRO devices (Page 24)
46
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
Operating Instructions, 07/2016, A5E31298376-AF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ifp1900Simatic ifp1500Simatic ifp1900 ethSimatic ifp1900 proSimatic ifp2200 pro

Table of Contents