Testing mechanical ambient conditions
The table below provides information on the type and scope of tests for mechanical ambient
conditions.
Tested for
Vibrations
Shock
Climatic ambient conditions
The following table shows the climatic ambient conditions for operation of the device.
Ambient conditions
Temperature built-in units:
Temperature PRO devices:
Relative humidity
Atmospheric pressure
Pollutant concentration
IFP1900 and IFP2200: From 0 to 45° C
1
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
Operating Instructions, 07/2016, A5E31298376-AF
Test standard
Vibration test in accordance
with IEC 60068, part 2-6
(sinusoidal)
Shock test in accordance
with IEC 60068, Part 2-27
Vertical mounting
Mounting at an angle
Vertical mounting
Inclined mounting
Comments
Type of vibration:
Frequency cycles at a rate of change of 1 octave/minute.
5 Hz ≤ f ≤ 8.4 Hz, constant amplitude 3.5 mm
8.4 Hz ≤ f ≤ 200 Hz, constant acceleration 1 g
Vibration duration:
10 frequency cycles per axis in each of the three
mutually vertical axes
Type of shock: Half-sine
Severity of shock:
Peak value 15 g, duration 11 ms
Direction of shock:
3 shocks in ± direction of axis in each of the three axes
vertical to each other
Permitted range
0 ... 50 °C (landscape format)
0 ... 40 °C (portrait format)
0 ... 40 °C (landscape format)
0 ... 35 °C (portrait format)
0 ... 45 °C (landscape format)
0 ... 45 °C (landscape format)
10 ... 90%, without condensation
1 080 to 795 hPa
SO
: < 0.5 vpm;
2
Relative humidity <60%,
no condensation
H
S: < 0.1 vpm;
2
Relative humidity <60%,
no condensation
Technical information
7.5 Technical specifications
Comments
1
Slope angle max. 35°
Tilt angle max. 45°
Corresponds to an elevation
of -1000 m to 2000 m
Test: 10 cm
/m
; 10 days
3
3
Test: 1 cm
/m
; 10 days
3
3