5.3 Alarm Related to Position Deviation between Axes Overflow Detection

5.3
Alarm Related to Position Deviation between Axes Overflow Detection
The alarm related to Position Deviation between Axes Overflow Detection is given in the follow-
ing table.
Alarm
Number
A.50D
All Axes
5-4
Alarm Name
Position Deviation between Axes
Overflow Alarm
Alarm Meaning
The position deviation between axes A and B during the
servo ON state exceeded the setting value of Pn66A (Posi-
tion Deviation Between Axes Overflow Alarm Level).