Mechanical installation
3.3 Installing the Braking Module
3.3.4

Installing the Braking Module in a Power Module frame size JX

Figure 3-9
Installing the Braking Module
The steps for the installation procedure are numbered in accordance with the figures in the
diagram.
1. Insert the Braking Module.
2. Screw in the 4 retaining screws for securing the Braking Module.
3. Secure the connection clip to the DC link (DCPA / DCNA) with 2 screws (Braking Module
connection) and 2 nuts (DC-link connection).
Note
Pay attention to the tightening torques
You must observe the tightening torques. Information on this can be found in the table in the
"Mechanical installation" section