2.4.1
Starting and configuring the SITOP monitor
Windows boot up
The SITOP monitor has to be started by Windows automatically during booting. A new value
has to be entered for the SITOP monitor under the key below in the Windows registry:
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Run
A script file, sitop.reg, is located in the E:\SITOP directory. The required key is entered into
the registry automatically if this file is executed.
The SITOP monitor is started automatically once the PCU is restarted. The next installation
step is to configure the monitor.
NOTICE
The SITOP monitor must not be started via the Windows Autostart directory.
General settings
The following settings must be made in the SITOP monitor configuration dialogue box:
● Parameterization of the interface: For module with USB port
● Parameterization of the change action:
PCU-Basesoftware (IM8)
Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
ValueName: SITOP
ValueType: REG_SZ
Value Data: E:\SITOP\SITOP_DC_USV.exe
The monitoring window display must be deselected, as this function can lead to sporadic
faults on the HMI operator interface.
Figure 2-3
Configuration of the SITOP monitor: General settings
Configuring the system
2.4 PCU 50.3 with SITOP UPS module
47