Siemens SINUMERIK Commissioning Manual page 523

Sinumerik 840di sl/840d sl/840dbase software and hmi advanced
Hide thumbs Also See for SINUMERIK:
Table of Contents

Advertisement

For dialogs, which are assigned to other operating areas:
\hmi\proj
\hmi\lng\...
\hmi\ico\...
In the PROGRAM operating area, the entire \cycles or \hmi directory is copied from the USB
memory to the /user/sinumerik directory on the CF card.
6.3.2
HMI Advanced
Overview
When using HMI Advanced, no control file entries are required.
The directories are searched for the configuration files in the specified order. If files of the
same name are stored in different directories, then the first file detected according to the
search strategy is interpreted.
Test on a PG/standard PC
To test the configured dialogs on a PG/standard PC, the following conditions apply:
● You have installed the PC version of the HMI Advanced software on your PC/PG.
● The directory structure is the same as on HMI Advanced.
● The error log is generated in: \DH\COM.DIR\ERROR.COM
Storing the alarm text files
Alarm text files are stored in the following directory: \DH\MB.DIR\
File name: ALUC_
References: HMI Advanced Startup Manual
Expanding the user interface
Commissioning Manual, 11/2006, 6FC5397-0DP10-0BA0
\cycles\ico
(Display image directory – contains only subdirectories for
each resolution)
\cycles\ico\ico640
Directory for the display images of resolution 640*480 as
.bmp or .bin
\cycles\ico\ico800
\cycles\ico\ico1024
xx
.COM
Configuring environment
6.3 Storage structure of configuration files
6-9