; (magazine list only)
; DELETE_TOOL_ON_UNLOAD=0
; 0=Do not process cutting edge parameters outside the tool type
; (default)
; 1=Process cutting edge parameters outside the tool type
; (if not equal to 0)
EDGE_PARAMS_OUT_OF_TOOLTYPE=1
; 0=display: Tool size left, right, top, bottom (default)
; 1=display: left, right
SHOW_TOOLSIZE_ONLY_LEFT_RIGHT=0
; Tool size display:
; True=display (default)
; False=do not display
; is only used if SHOW_TOOLSIZE_ONLY_LEFT_RIGHT = 0
; (or default)
SHOW_TOOLSIZE_COMPONENTS=left:=True, right:=True, top:=True,
bottom:=True
; The function "Activate D check" refers to:
; -1=all magazines with distance relationship to spindle/toolholder
; (default)
; 1=current magazine only
DCHECK_ACTIVATE=-1
; The "Activate D check" function can be carried out automatically
; when the working offset list is opened
; False=function can only be activated via softkey (default)
; True=function is automatically carried out when the working offset
; list is opened
DCHECK_AUTO_ACTIVATE=False
; DCHECK_AUTO_ACTIVATE_MODE is only used
; if DCHECK_AUTO_ACTIVATE=True
; 0=The "Activate D check" function is carried out automatically
; when the working offset list is opened, even in the main screen
, (contains "R parameters" softkey) (default)
; 1=The "Activate D check" function is carried out automatically
; when the working offset list is opened, but not in the
; main screen (contains "R parameters" softkey). Same behavior as
before
; implementation of DCHECK_AUTO_ACTIVATE_MODE
; (prior to HMI Advanced 06.03.19).
; Buffer location display:
; DB: Original name from the magazine configuration from the
database
; no locale-dependent texts
; DLL: Name = text from the language-DLL + index (default)
; Example: Spindle1, language-specific texts
NameOfBufferPlaceFrom=DB
; To display the "Create cutting edge" and "Delete cutting edge"
functions
; (only possible with multi-line display) in the
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0