Maximum Temperature Setting
Before using the shower, the maximum temperature level must be checked to make
sure that it is safe. It has been preset to approximately 43°C at the factory, but due
to variations in site conditions the maximum temperature may need adjustment.
Note! Make sure that the hot water temperature is at least 55°C and that there is
a suffi cient supply.
Turn on the shower to maximum fl ow and temperature (i.e. both controls fully
anticlockwise) and allow the temperature to stabilise.
If the temperature is too hot or too cold adjust as follows:
Using the 2.5 mm Hexagon Key provided, unscrew and remove the Temperature
1.
Control Handle
Insert the 2.5 mm Hexagon Key into the centre of the Green Hub and engage
2.
with the hidden Temperature Adjust Screw.
Turn the Hexagon Key until the required maximum showering temperature
3.
is obtained. Turn anticlockwise to increase or clockwise to decrease the
temperature (
Once the desired maximum blend temperature has been achieved, turn off the
4.
shower.
Refi t the Temperature Control Handle.
5.
Check that the showering temperature is correct. If the correct temperature
6.
setting cannot be achieved, refer to section: "Fault Diagnosis" for possible
cause and rectifi cation.

COMMISSIONING

turn = approximately 1°C).
¼
-
+
Temperature
Handle
30
-
+