2.0 INSTALLATION INSTRUCTIONS (Continued)
8. Connect steam line (3/4" pipe size) to the kettle, making sure there is steam control valve
strainer fairly convenient to the kettle. If incoming steam pressure is greater than kettle
maximum operating pressure, a pressure reducer valve must be installed in the line. A
steam line pressure gauge is recommended to determine amount of actual steam coming to
the unit. Safety relief valve must not be plugged as it relieves excess pressure in the
kettle.
9. Connect water line (½" pipe size) to appliance as shown in service connections.
10.
Connect kettle condensate return line and water return line to drain or boiler return line.
Boiler return line must have a check valve.
11.
Check for proper operation.