Carrier Wave Frequency Setting
Settable carrier wave frequency range is different for different carrier waveforms. Default frequency of
all carrier wave is 1kHz. The frequency setting range of each carrier wave can be seen in the following
table:
Carrier
UTG1010A
Wave
Minimum
Value
Sine
1μHz
Wave
Square
1μHz
wave
Ramp
1μHz
Wave
Arbitrary
1μHz
Wave
If need to set carrier frequency, please press Parameter→ Frequency softkey, then enter required
numerical value, and select unit after selecting carrier waveform.
Modulation Source Selection
This device can select internal modulation source or external modulation source. After enabling AM
function, the default modulation source is internal. If need to change press
Parameter→ModulationSource→External in turn.
1) Internal Source
When modulation source is internal, modulation wave can be: sine wave, square wave, rising ramp
wave, falling ramp wave, arbitrary wave and noise. After enabling AM function, the default of
modulation wave is sine wave. If need to change it, press Carrier Wave →Parameter→Type in turn.
Frequency
Maximum
Minimum
Value
Value
10MHz
1μHz
5MHz
1μHz
400kHz
1μHz
2MHz
1μHz
23
UTG1000A Series Function Generator User Manual
UTG1005A
Maximum Value
5MHz
5MHz
400KHz
1MHz