Natural Gas Hook-Up - Napoleon GPFL48 Manual

Linear patioflame
Hide thumbs Also See for GPFL48:
Table of Contents

Advertisement

6. Unscrew the propane orifice from the inside of the burner as illustrated.
7. Replace the propane orifice with the natural gas orifice supplied.
Note: The air shutter has been factory set and does not need to be adjusted.
8. Reconnect the stainless steel flex connector to the orifice and tighten using (2) wrenches.
9. Place the glass tray over the burner and fasten to the patio flame with the screws removed in step 2.
10. Fill out the conversion label included with your patio flame and apply it to the inside of the control
panel access door.
11. A leak test must be performed according to the leak testing instructions found in the manual.

Natural Gas Hook-Up

The gas appliance is designed to operate at an inlet pressure of 7 inches water column. The piping up to
the appliance is the responsibility of the installer. A flexible metal connector is included to simplify the
installation of the unit. Connect the flexible connector to rigid
pipe, copper tube or an approved flexible metal connector, which
complies with Z21.4/CSA 6.10. If using a gas hose (not supplied)
connect the flared end of the hose to the connector on the end
of the flex tube as illustrated. Tighten using two wrenches. (Do
not use thread sealer/pipe dope.) Leak test all joints prior to using
the appliance. Piping and valves upstream of the quick discon-
nect are not supplied. The gas supply pipe must be sufficiently
sized to supply the BTU/h specified on the rating plate, based on
the length of the piping run. The quick disconnect must not be
installed in an upward direction and a readily accessible manual shut-off valve must be installed upstream
of, and as close to, the quick disconnect as is feasible.
Purge the gas supply line of any trapped air prior to the first firing of the unit.
WARNING!
The installation must be performed by a licensed gas fitter, and all connections must be leak tested
before operating the appliance.
Ensure all hose connections are tightened using two wrenches. Do not use Teflon tape or pipe dope
on any hose connection.
Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
fire.
Locate the hose out of pathways where people may trip over it or in areas where the hose may be
subject to accidental damage.
Leak test all the connections using a soap and water solution as per the leak testing instructions
found in the manual.
N415-0293 OCT 09.17