INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CR97-003 ● CAN-2.21-M85 ● IAS US. 4-96
OUTDOOR
GSST8N

NATURAL GAS

GSST8P
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
WARNING: FOR OUTDOOR USE ONLY
W415-0689 / A / 06.08.10
1.2A
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Tourch GSST8N

  • Page 1: Natural Gas

    - Installation and service must be performed by a qualifi ed installer, service agency or the supplier. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com W415-0689 / A / 06.08.10...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION INSTALLATION INSTALLATION CLEARANCES GAS INSTALLATION COMBUSTION AND VENTILATION AIR FRAMING CLEARANCES TO COMBUSTIBLES FINISHING TMCSS MOUNTING CABINET INSTALLATION RAIN TABS DOOR REMOVAL TFSSO FRAME INSTALLATION LOGO PLACEMENT GLASS MEDIA INSTALLATION LK8 LIGHT INSTALLATION (OPTIONAL) ELECTRICAL INFORMATION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Door, see “DOOR REMOVAL / INSTALLATION” section. Cabinet, see “MOUNTING CABINET INSTALLATION” section. Frame, see “FRAME / Glass, see “GLASS FRONT INSTALLATION” REMOVAL / INSTALLATION” section. section. Rating plate, see “RATING PLATE INFORMATION” section. W415-0689 / A / 06.08.10...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi re or injury. •...
  • Page 5: Dimensions

    DIMENSIONS ” ” 6 ” 15” ELECTRICAL GAS LINE 13” 1 ½” ACCESS ACCESS GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
  • Page 6: General Information

    THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example in Massachusetts State: •...
  • Page 7: Rating Plate Information

    RATING PLATE INFORMATION RATING LABEL LOCATION: THE RATING LABEL IS LOCATED UNDER THE CONTROL PANEL AND IS CHAINED TO THE APPLIANCE. DO NOT REMOVE. CERTIFIED UNDER : CGA CR97-003 (July, 1997) CSA US Req. 4-96, 3rd Ed. OUTDOOR GAS FIREPLACE .
  • Page 8: Installation

    3.0 INSTALLATION INSTALLATION CLEARANCES INSTALLATIONS CANADA U.S.A. 8 INCHES 8 INCHES Clearance above grade, veranda porch, deck or balcony. 12 INCHES 9 INCHES Clearance to windows or doors that open. 12 INCHES* 12 INCHES* Clearance to permanently closed windows. 18 INCHES** 18 INCHES** Vertical clearance to ventilated soffi...
  • Page 9: Gas Installation

    GAS INSTALLATION WARNING ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE. DO NOT USE OPEN FLAME. The appliance is designed to accept a 1/2” gas 3.2.1 supply line. The appliance is equipped with a 1/2” manual shut-off valve. The access to the gas inlet is located in the bottom 3.2.2 of the cabinet.
  • Page 10: Framing

    4.0 FRAMING WARNING YOUR APPLIANCE IS DESIGNED FOR OUTDOOR APPLICATION ONLY. THE APPLIANCE MUST BE IN- STALLED IN THE CABINET PROVIDED. THE CABINET IS DESIGNED TO BE INSTALLED ON FINISHED SURFACES. YOUR APPLIANCE CAN BE RECESSED INTO A STRUCTURE A MAXIMUM OF 12” PROVIDED THAT ALL CLEARANCES ARE MAINTAINED.
  • Page 11: Finishing

    5.0 FINISHING TMCSS MOUNTING CABINET INSTALLATION WARNING BEFORE STARTING THE INSTALLATION, REMOVE THE PROTECTIVE LAYER FROM ALL THREE COMPONENTS THAT MAKE UP THE GSST8 (CABINET, FRAME AND TORCH). NOTE: It is recommended that all fasteners be INSTALLATION stainless steel. TEMPLATE Using the installation template (W122-0401) 5.1.1 supplied, determine the best mounting location...
  • Page 12: Rain Tabs

    Start the fasteners into each 5.1.3 of the six remaining mount- ing holes. Align the keyholes of the frame to the heads of the fasteners and slide the frame down onto the fasten- ers. Ensure the frame is plumb and level before tightening the fasteners.
  • Page 13: Door Removal

    DOOR REMOVAL WARNING GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED. DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED. FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE.
  • Page 14: Tfsso Frame Installation

    TFSSO FRAME INSTALLATION Hang the frame onto the fi rebox by en- 5.4.1 gaging the top trim bracket into the slot in the top of the frame and the bottom hooks of the frame into the slot in the mounting cabinet. SLOT TRIM BRACKET...
  • Page 15: Glass Media Installation

    GLASS MEDIA INSTALLATION WARNING CLEAN THE GLASS MEDIA PRIOR TO INSTALLATION. BEFORE APPLYING THE CLEANED GLASS, ENSURE THAT IT IS DRY. DO NOT CHANGE OR SUBSTITUTE THE GLASS MEDIA MATERIAL PROVIDED WITH THIS APPLIANCE. IF REPLACING, USE ONLY THE REPLACEMENT GLASS MEDIA AVAILABLE FROM YOUR AUTHORIZED DEALER / DISTRIBUTOR.
  • Page 16: Lk8 Light Installation (Optional)

    LK8 LIGHT INSTALLATION (OPTIONAL) Turn off the electrical and gas supply to the appli- 5.7.1 ance. Remove the frame from the unit by removing the 2 5.7.2 stainless steel hex head securing screws from the bottom and lifting the frame off of the top trim bracket. Lay the frame down on its front, being careful not to 5.7.3 scratch the fi...
  • Page 17: Electrical Information

    6.0 ELECTRICAL INFORMATION WARNING RISK OF ELECTRIC SHOCK! CONTROL AND VALVE OPERATE WITH 110V. DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SER- VICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE ELECTRICAL CIRCUIT.
  • Page 18: Operation

    7.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Ensure that a continuous gas fl ow is at the burner before installing the door. When lit for the fi rst time, the fi...
  • Page 19: Adjustments

    8.0 ADJUSTMENTS GAS PRESSURE ADJUSTMENT Outlet pressure can be adjusted if not measuring 3.5” W.C. (NG) or 10.0” W.C. (LP). NPT BARB Pressure can be checked by removing cap (A) using a 8.1.1 FITTING 3/16 Allen key and replacing it with a 1/8 NPT barb fi tting. Place pressure gauge tube over the fi...
  • Page 20: Maintenance

    9.0 MAINTENANCE MAINTENANCE MAINTENANCE WARNING MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 21: Door Glass Replacement

    DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 22: Replacements

    W455-0085 NATURAL GAS ORIFICE W455-0086 PROPANE GAS ORIFICE W475-0590 BACK PANEL W300-0108 ACCENT GLASS (BLACK) W562-0046 ROPE GASKET, BACK PANEL W385-0334 NAPOLEON® LOGO W475-0595 CONTROL PANEL W385-0380 CONTROL PANEL LABEL W660-0082 OUTDOOR ON/OFF SWITCH ACCESSORIES REF NO. PART NO. DESCRIPTION...
  • Page 23 Items not shown to scale. W415-0689 / A / 06.08.10...
  • Page 24: Trouble Shooting

    11.0 TROUBLE SHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 25 SYMPTOM PROBLEM TEST SOLUTION No gas to the Switch is defective. Connect a jumper wire across the wall switch main burner; terminals; if main burner lights, replace switch / switch is on. thermostat. Burner orifi ce is blocked. Remove stoppage in orifi ce. Control valve faulty.
  • Page 26: Warranty

    After the fi rst year, with respect to this Limited Warranty, NAPOLEON® may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
  • Page 27: Service History

    13.0 SERVICE HISTORY 43.1 W415-0689 / A / 06.08.10...
  • Page 28 14.0 NOTES 44.1 W415-0689 / A / 06.08.10...