Download Print this page
Elkay EDFPVR217RC Installation, Care & Use Manual

Elkay EDFPVR217RC Installation, Care & Use Manual

Non-refrigerated composite vr fountain

Advertisement

Quick Links

Installation/Care/Use manual
Non-Refrigerated Composite VR Fountain
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION
FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
After installation, leave these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
3/8" O.D. UNPLATED COP-
1/4" O.D. TUBE
PER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
FIG. 1
EDFPVR217RC
with Back Panel
IMPORTANT
IMPORTANT! INSTALLER PLEASE NOTE.
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
FIG. 2
Page 1
TUBE IS
PUSH IN COLLET
SECURED
TO RELEASE TUBE
IN POSITION
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
98409C (Rev. F - 08/18)

Advertisement

loading

Summary of Contents for Elkay EDFPVR217RC

  • Page 1 EDFPVR217RC Installation/Care/Use manual Non-Refrigerated Composite VR Fountain with Back Panel Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
  • Page 2 EDFPVR217RC 98409C (Rev. F - 08/18 Page 2...
  • Page 3 EDFPVR217RC EDFPVR217RC Install Instructions Attach the back panel to the wall using the top two holes (1) and (2) in panel. Do not tighten the back panel down, allow some slack for sliding the fountain over bolts. Slide fountain onto partial secured bolts and tighten down at (1) and (2).
  • Page 4: Troubleshooting And Maintenance

    8. Replace bottom access panel to fountain basin using screws provided. Tighten securely. Care and Maintenance of Halsey Taylor Marblyte Fountains Elkay Composite fountains provide an extremely durable, nonporous surface which resists staining. Care is very simple. Routine cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is normally needed to give many years of trouble free service.
  • Page 5 VANDAL RESISTANT BUBBLER DETAIL FIG. 7 FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 PRINTED IN U.S.A. ELKAY MANUFACTURING COMPANY • 2222 • CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com 98409C (Rev. F - 08/18) Page 5...