Water Flow Servo Circuit
9.
a.) Disconnect relay connector (G
Water Flow Servo.
Normal: 10~30
If normal, proceed to b.
Faulty: Replace Water Flow Servo and Water Flow Sensor.
b.) Disconnect relay connector (G
(-) on PCB unit side.
Normal: DC11~13V
If normal: proceed to c).
Faulty: Replace PCB unit.
c.) Measure voltage between Brown and Grey with relay connector (G
no water flowing, water flow servo fully open).
Normal: DC4~6V
Faulty: Replace Water Flow Servo with Water Flow Servo.
d.) Measure voltage between Yellow and Grey with relay connector (G
no water flowing, water flow servo fully open).
Normal: < DC1.0V
Faulty: Replace Water Flow Servo and Water Flow Sensor.
10. Heat Exchanger Outlet Thermistor Circuit (G
Check Heat Exchanger Outlet Thermistor if error indicator "33" is displayed.
Disconnect relay connector (G
Circuit Break: Resistance > 1M
Short Circuit: Resistance < 1
If normal, proceed to Water Flow Servo Circuit
If faulty, replace Heat Exchanger Outlet Thermistor.
Note: For controller readout of thermistor temperature whilst operational refer
maintenance monitor (chapter 17) No. 11.
Infinity REU-VRM3237WG / HD250e REU-VRM3237WC
(G
)
6
), and measure resistance between Red and Blue of
6
), and measure voltage between Orange (+) and Grey 
6
)
4
) and measure resistance between White and Pink.
4

- 24 -
) connected (with
6
) connected (with
6
Issue 1 - 19/05/09 ©Rinnai