12. Diagnostics Points

FLOW
COMPONENT
CHART
No.
1
SURGE PROTECTOR
2
WATER FLOW
CONTROL DEVICE
17
BY-PASS FLOW
3
CONTROL DEVICE
4
WATER CONTROLLER
5
WATER FLOW SENSOR
6
COMBUSTION FAN
7
FLAME ROD
8
MODULATING VALVE
9
OUTGOING THERMISTOR
HEAT EXCHANGER
10
OUTGOING THERMISTOR
12
THERMAL FUSE
13
IGNITER
14
MAIN SOLENOID VALVE
15
SOLENOID VALVE 1
16
SOLENOID VALVE 2
17
SOLENOID VALVE 3
Infinity REU-VR3237WG /HD250e REU-VRM3237WC
MEASUREMENT POINT
CN
WIRE COLOUR
D
B-Br
1
R-B
Gy-O
BELOW DC1V(LIMITER ON)
G
Gy-Y
6
DC4〜6V(LIMITER OFF)
BELOW DC1V(LIMITER ON)
Gy-Br
DC4〜6V(LIMITER OFF)
Br-W
DC12V(OPERATING DC2〜6V)
O-W
H
Y-W
1
R-W
GND
A
Bk-Bk
1
R-Bk
G
3
Y-Bk
DC4〜7V(PULSE 17〜460Hz)
GND
R-Bk
B
Y-Bk
1
W-Bk
GND
DC6〜45V
Y-BODY EARTH
E
1
Y-FLAME ROD
E
P-P
2
W-W
G
5
G
W-P
4
G
1
R-R
W-W
E
3
C
Gy-Gy
1
F
P-Bk
1
F
R-Bk
2
F
O-Bk
3
F
Y-Bk
4
- 15 -
NORMAL VALUE
AC207〜264V
DC11〜13V
DC11〜13V
15〜35Ω
DC11〜13V
DC11〜13V
DC6〜45V
DC11〜13V
(33〜400Hz)
AC5〜150V
OVER DC1μA
DC2〜15V
67〜81Ω
15°C... 11.4〜 14.0kΩ
30°C... 6.4〜 7.8kΩ
45°C... 3.6〜 4.5kΩ
60°C... 2.2〜 2.7kΩ
105°C... 0.6〜 0.8kΩ
BELOW 1Ω   
AC207〜264V
DC11〜13V
37〜43Ω
DC11〜13V
37〜43Ω
DC11〜13V
37〜43Ω
DC11〜13V
35〜41Ω
NOTE
OPERATE ELECTRICITY
CONTROL ELECTRICITY
FULL OPEN POSITION
FULL CLOSE POSITION
ON2.7l/MIN (30Hz)
OVER 1800PULSE/MIN
OFF2.0l/MIN(20Hz)
BELOW 1200PULSE/MIN
AFTER IGNITION
FLAME CONDITION
Issue 1 - 19/05/09 ©Rinnai