4.
Main Solenoid Valve (F
Check the main solenoid if error indicator "11" is displayed.
a.) Disconnect Main Solenoid connector and measure resistance between Pink and Black.
Normal: 37~43
If normal, proceed to b).
Faulty: Replace Main Solenoid.
b.) Measure voltage between Pink-Black of Main Solenoid connector.
Normal: DC11~13V
If normal, proceed to Solenoid Valve F
Faulty: Replace PCB.
4b.Solenoid Valve 1 (F
Check Solenoid 1 if error indicator "11" is displayed.
a.) Disconnect Solenoid 1 connector and measure resistance between Red and Black.
Normal: 37 ~ 43
If normal, proceed to b).
Faulty: Replace Solenoid 1.
b.) Measure voltage between Red and Black of Solenoid 1 connector.
Normal: DC 11 ~ 13V
If normal, proceed to Solenoid Valve 2 (F
Faulty: Replace PCB.
4c. Solenoid Valve 2 (F
a.) Disconnect Solenoid Valve 2 connector and measure resistance between Orange and
Black.
Normal: 37 ~ 43
If normal, proceed to b).
Faulty: Replace Solenoid Valve 2.
b.) Measure voltage between Orange and Black of Solenoid Valve connector.
Normal: DC 1H3V
If normal, proceed to Thermal fuse Circuit.
Faulty: Replace PCB.
Infinity REU-VRM3237WG / HD250e REU-VRM3237WC
) Circuit
1
2
) Circuit
2
) Circuit
3
) Circuit
3
- 20 -
Issue 1 - 19/05/09 ©Rinnai