Installing A Hot-Swap Ac Power Supply - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

Installing a hot-swap ac power supply

The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
About this task
The following notes describe the type of ac power supply that the server supports
and other information that you must consider when you install a power supply:
v Make sure that the devices that you are installing are supported. For a list of
supported optional devices for the server, see http://www.ibm.com/systems/
info/x86servers/serverproven/compat/us/.
v Before you install an additional power supply or replace a power supply with
one of a different wattage, you may use the IBM Power Configurator utility to
determine current system power consumption. For more information and to
download the utility, go to http://www-03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
v The server comes with one hot-swap 12-volt output power supply that connects
to power supply bay 1. The input voltage is 100-127 V ac or 200-240 V ac
auto-sensing.
v Power supplies in the server must be with the same power rating or wattage to
ensure that the server will operate correctly. For example, you cannot mix
750-watt and 900-watt power supplies in the server.
v Power supply 1 is the default/primary power supply. If power supply 1 fails,
you must replace the power supply immediately.
v You can order an optional power supply for redundancy.
v These power supplies are designed for parallel operation. In the event of a
power-supply failure, the redundant power supply continues to power the
system. The server supports a maximum of two power supplies.
Statement 5
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current from
the device, ensure that all power cords are disconnected from the power source.
Statement 8
125
Chapter 4. File module

Advertisement

Table of Contents
loading

Table of Contents