Service And Maintenance; Servicing And Maintenance - Siemens SIWAREX WL270 CP-S SB Operating Instructions Manual

Pressure piece set
Hide thumbs Also See for SIWAREX WL270 CP-S SB:
Table of Contents

Advertisement

Service and maintenance

6.1

Servicing and maintenance

Important notes on cleaning
CAUTION
Damage to load cells, measurement errors
 Dirt must not be allowed to accumulate in the vicinity of a load cell.
 Do not subject cable glands, sealing elements and flat seals directly to the jet from a
 Do not clean the load cell and installed parts with aggressive cleaning agents. This can
Pressure piece set
● Check the pressure piece set according to the ambient conditions.
● Keep the pressure piece set free of dirt.
● Check the bearing surfaces of the load cells:
Overload protection
Personal injury and damage to property
Dirty, frozen or incorrectly adjusted overload protection elements lead to erroneous
measurements due to blockage or to an overflow of the scale. Personal injury and material
damage may occur.
● Regularly check the existing overload protection elements:
CP-S SB
Operating Instructions, 11/2010, A5E03323543B
high-pressure hose.
even cause corrosion to stainless steel if not used correctly.
Select the servicing intervals based on the emergence of dust, dirt and moisture.
– Clean the bearing surfaces as required.
– Grease the bearing surfaces as needed.
WARNING
– Select the servicing intervals based on the emergence of dust, dirt and moisture.
– Keep the overload protection elements free of dirt and ice.
– Check the settings for the overload protection elements.
– Re-adjust (correct) the overload protection as needed.