Preparing The Pressure Piece Set; Installing The Load Cell With Pressure Piece Set - Siemens SIWAREX WL270 CP-S SB Operating Instructions Manual

Pressure piece set
Hide thumbs Also See for SIWAREX WL270 CP-S SB:
Table of Contents

Advertisement

5.2.4

Preparing the pressure piece set

Figure 5-2
1. Unpack the pressure piece set.
2. Read the accompanying information sheet.
3. Check the delivered unit.
See also
Scope of delivery (Page 5)
5.2.5

Installing the load cell with pressure piece set

Death or serious bodily injury
A falling load bearing implement can lead to serious bodily injury or considerable material
damage depending on the potential risk.
CAUTION
Damaging of load cells
Incorrect or incomplete installation can result in damage to the load cells, installed parts
and the load bearing implement.
Observe the warning notices at the start of the chapter, see:
Plane of the mounting surfaces
A plane of ≤ 0.2 mm is required for the mounting surfaces.
CP-S SB
Operating Instructions, 11/2010, A5E03323543B
Upper pressure piece
Lower pressure piece
Scope of delivery
WARNING
5.2 Mounting the pressure piece set
Installation