Carrier WeatherExpert 48LC 04 Series Installation Instructions Manual page 41

Single package rooftop gas heating/electric cooling unit with puron (r-410a) refrigerant
Table of Contents

Advertisement

PARAMETER
PARAMETER
GROUP
NUMBER
3005
3006
FAULT
3007
FUNCTIONS
3008
3009
3104
AUTOMATIC
3105
RESET
3106
5301
5302
EFB PROTOCOL
5303
5304
5305
OPTIONS
9802
PARAMETER
PARAMETER
GROUP
NUMBER
9902
9905
9906
START-UP
DATA
9907
9908
9909
1001
START/STOP/
DIR
1003
1103
REFERENCE
1104
SELECT
1105
1201
1202
CONSTANT
SPEEDS
1203
1204
1301
ANALOG
INPUTS
1302
1401
RELAY
1402
OUTPUTS
1403
Table B — 48LC 04-06 VFD Parameters (cont)
UNIT SIZE
48LC 04
Motor
2.4 HP 460v
Description
Drive/motor
460v
Voltage
Motor Part
HD56FE653
Number
VFD Part
HK30WA008
Number
ACH550-
ABB Part
CARUH
Number
-06A9-4
Motor Therm Prot
(1) Fault
Motor Thermal
1050 s
Time
Motor Load
100%
Curve
Zero Speed Load
%00705
Break Point
35 Hz
Frequency
AR Overcurrent
(0) DISABLE
AR Overvoltage
(1) ENABLE
AR Undervoltage
(1) ENABLE
EFB PROTOCOL
0601 (hex)
ID
EFB STATION ID
41
EFB BAUD
38400
RATE
EFB PARITY
8 NONE 1
EFB CTRL
DCU PROFILE
PROFILE
COMM PROT
6 (LEN)
SEL
Table C — 48LC 05-06 VFD Parameters
UNIT SIZE
2.4 HP 208-
Motor Description
230v
Drive/Motor Voltage
208-230v
Motor Part Number
HD56FE653
VFD Part Number
HK30WA001
ACH550-
ABB Part Number
CARUH
-012A-2
(1) HVAC
Application Macro
DEFAULT
Motor Nominal Voltage
Motor Nominal Current
Motor Nominal
Frequency
Motor Nominal Speed
1725
Motor Nominal Power
EXT1 Commands
(1) DI1
Direction
(1) Forward
REF1 Select
(1) AI1
REF1 Minimum
0 Hz
REF1 Maximum
60 Hz
Constant Speed Select
(8) DI2,3
Constant Speed 1
42.6
Constant Speed 2
60 Hz
Constant Speed 3
60 Hz
Minimum AI-1
20.00%
Maximum AI-1
100.00%
Relay Output 1
(1) Ready
Relay Output 2
(2) Run
(16) FLT/
Relay Output 3
ALARM
1.7 HP 575v
1.7 HP 208-230v
575v
HD56FR579
HD56FR233
HK30WA048
HK30WA045
ACH550-
CARUH
-03A9-6
(1) Fault
1050 s
100%
%00705
35 Hz
(0) DISABLE
(0) DISABLE
(1) ENABLE
(1) ENABLE
(1) ENABLE
(1) ENABLE
0601 (hex)
41
38400
8 NONE 1
DCU PROFILE
DCU PROFILE
6 (LEN)
48LC 06
2.4 HP 460v
460v
HD56FE653
HK30WA008
ACH550-
CARUH
-06A9-4
(1) HVAC
DEFAULT
230
460
7.9
4.0
60
60
1725
2.4
2.4
(1) DI1
(1) Forward
(1) AI1
0 Hz
60 Hz
(8) DI2,3
42.6
60 Hz
60 Hz
20.00%
100.00%
(1) Ready
(2) Run
(16) FLT/
ALARM
41
48LC 05
1.7 HP 460v
208-230v
460v
HD56FR463
HK30WA046
ACH550-
ACH550-
CARUH
CARUH
-07A5-2
-04A1-4
(1) Fault
(1) Fault
1050 s
1050 s
100%
100%
%00705
%00705
35 Hz
35 Hz
(0) DISABLE
(1) ENABLE
(1) ENABLE
0601 (hex)
0601 (hex)
41
41
38400
38400
8 NONE 1
8 NONE 1
DCU PROFILE
6 (LEN)
6 (LEN)
48LC 05/06
2.9 HP 208-
2.9 HP 460v
230v
208-230v
460v
HD58FE654
HD58FE654
HK30WA001
HK30WA008
ACH550-
ACH550-
CARUH
CARUH
-012A-2
-06A9-4
(1) HVAC
(1) HVAC
DEFAULT
DEFAULT
230
460
9.2
4.6
60
60
1725
1725
2.4
2.4
(1) DI1
(1) DI1
(1) Forward
(1) Forward
(1) AI1
(1) AI1
0 Hz
0 Hz
60 Hz
60 Hz
(8) DI2,3
(8) DI2,3
41.2
41.2
60 Hz
60 Hz
60 Hz
60 Hz
20.00%
20.00%
100.00%
100.00%
(1) Ready
(1) Ready
(2) Run
(2) Run
(16) FLT/
(16) FLT/
ALARM
ALARM
48LC 06
2.4 HP 575v
575v
HD56FE577
HK30WA048
ACH550-
CARUH
-03A9-6
(1) Fault
1050 s
100%
%00705
35 Hz
(0) DISABLE
(1) ENABLE
(1) ENABLE
0601 (hex)
41
38400
8 NONE 1
DCU PROFILE
6 (LEN)
3.7 HP 575v
575v
HD58FE577
HK30WA021
ACH550-
CARUH
-06A1-6
(1) HVAC
DEFAULT
575
4.2
60
1725
2.4
(1) DI1
(1) Forward
(1) AI1
0 Hz
60 Hz
(8) DI2,3
41.2
60 Hz
60 Hz
20.00%
100.00%
(1) Ready
(2) Run
(16) FLT/
ALARM

Advertisement

Table of Contents
loading

Table of Contents