Setting Elements With Standard Interface - Siemens SIMODRIVE 611A Installation And Planning Manual

Transistor pwm inverters and motors for ac feed drives
Table of Contents

Advertisement

04.97
12.94
07.94
Start–up, supplementary functions

Setting elements with standard interface

Setting elements, switch S2 and S3 or S5 and S6 for the 2nd axis
1) As supplied
2) Acts on the BB relay of the NE/monitoring module. If the user–friendly and standard interface are used together, or
just the standard interface alone, then the BB relay on the NE module drops–out if there is no enable signal or a
fault is present.
3) Function only for 2–axis version
4) The slave axis must be operated in the current–controlled mode with enabled I component.
Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and Start–Up Guide/IAA/–04.97 Edition
3.1 Settings elements with standard interface
S2/S5 contacts
10 x DIL
1
Motor clockwise direction of
rotation for a positive speed set-
point (motor shaft, drive end) at
terminal 56/14
2...5
Curr. normal. (I
6...9
Current controller gain (0.5)
10
Speed–controlled operation
S3/S6 contacts
Function
8 x DIL
1
Speed setpoint smoo-
thing
2
Speed actual value
smoothing
3
Speed controller smoo-
thing
4
Current setpoint smoo-
thing
5
Speed contr. adaptation
2)
6
Ready/fault
3)4)
7
Master/slave
8
Current–controlled opera-
tion
Feed modules (VS)
OFF
Motor counter–clockwise direc-
tion of rotation for a positive
speed setpoint (motor shaft, drive
1)
end)
at terminal 56/14
1)
=100 %)
Curr. normal. (I
max
1)
Current controller gain (11.5)
1)
Current–controlled operation
OFF
1)
No smoothing
1)
No smoothing
1)
No smoothing
1)
No smoothing
1)
OFF
Ready to run si-
1)
gnal
1)
Master
With I component
ON
= 23 %)
max
ON
With τ = 2.2 ms
With τ = 280 µs
With τ = 370 µs
With τ = 110 µs
ON
Fault signal
4)
Slave
Without I compo-
1)
nent
1-103