Disassembly Of Freezer Parts; Figure 12 Auger Flight Wear & Front Auger Support Bushing Wear - Stoelting U421/U444 Owner's Manual

Cab model soft-serve pressurized freezer
Table of Contents

Advertisement

As a recommended cleaner and sanitizer for your
frozen dessert machine, STERA-SHEEN has proven
to be one of the best daily maintenance products for:
·
CLEANING – Thorough removal of all solids
including butterfat and milk fat.
·
MILKSTONE REMOVAL – Complete removal of
milkstone.
·
SANITIZING – FDA-approved no rinse sanitizer
for food contact surfaces.
Additional Information
THE USE OF DELIMERS
A delimer is a strong acid that has the ability to
dissolve milkstone. This type of chemical may
become necessary once high levels of milkstone
have developed. While these products are very
effective for removing HIGH levels of milkstone, they
are not ideal for two reasons:
1.
PRODUCT SAFETY – Strong acids are
dangerous chemicals and handling them
requires safety
2.
MACHINE DAMAGE – Strong acids will attack
metal and rubber causing premature wear of
parts. The use of a delimer needs to be closely
monitored to avoid damage to machine surfaces
and parts.
With proper daily use of STERA-SHEEN or it's
equivalent, there is no need for the use of a
DELIMER.
DO NOT USE BLEACH
·
BLEACH HAS ABSOLUTELY NO CLEANING
PROPERTIES.
·
BLEACH IS CORROSIVE. It can and will
damage components of the machine causing
premature wear and metal corrosion.
GENERAL PURPOSE CLEANERS
General purpose cleaners do not have the ability to
remove milkstone. Milkstone will become a problem
if not remedied with additional products and
procedures.
THE USE OF CHLORINE TEST STRIPS
"Test strips" are used to determine concentrations of
active chlorine in sanitizing solutions. To use the
strips, tear off a small portion and submerge it into
the sanitizing solution. Then, compare the color
change to the color key on the side of the test strip
dispenser to determine the approximate chlorine
concentration.
The ideal concentration of chlorine needs to be 100
ppm (as stated by the FDA).
Follow the directions on the container for proper
concentration.
There are two main factors that contribute to falling
chlorine concentrations in a sanitizing solution.
1.
PRODUCT USE – As the chlorine in the
solution is being used, chlorine concentrations
fall.
2.
TIME – As time passes, small amounts of
chlorine "evaporate" from the solution. (That is
why you can smell it.)
Sanitizing solutions should not be allowed to fall
below 100 ppm chlorine. New solutions should be
mixed once old solutions become ineffective.

3.4 DISASSEMBLY OF FREEZER PARTS

Moving machinery can grab, mangle and dis-
member. Place the CLEAN-OFF-SERVE toggle
switch in the OFF position before disassembling
for cleaning or servicing. Placing the CLEAN-OFF-
SERVE toggle switch in the SERVE position dur-
ing cleaning or servicing may result in serious
personal injury.
Before using the freezer for the first time, complete freezer
disassembly, cleaning and sanitizing procedures will need
to be followed. Routine cleaning intervals and procedures
must comply with the local and state health codes.
Inspection for worn or broken parts should be made at
every disassembly of the freezer for cleaning or other
purposes. All worn or broken parts should be replaced to
ensure safety to both the operator and the customer and
to maintain good freezer performance and a quality prod-
uct. Two normal wear areas are the auger flights and front
auger support bushing (see Figure 12).
To disassemble the freezer, refer to the following steps:
Wear Line
Figure 12. Auger Flight Wear & Front Auger
Support Bushing Wear
12
NOTE
WARNING

Advertisement

Table of Contents
loading

This manual is also suitable for:

U421U444

Table of Contents