Condenser Cleaning (Air Cooled Freezers); Preventative Maintenance; Extended Storage; Error Codes - Stoelting F431 Owner's Manual

Cab model soft-serve pressurized freezer
Hide thumbs Also See for F431:
Table of Contents

Advertisement

Figure 31. Removing Condenser Filter
Belt life will be increased if new drive belts are tight-
ened after two or three weeks of operation.
4.7 CONDENSER CLEANING
The condenser requires periodic cleaning. To clean the
condenser, refer to the following steps:
A.
Lift the condenser filter off the freezer cover panel.
Visually inspect the condenser filter for dirt (see
Figure 31).
B.
If the condenser filter is dirty, vacuum or brush clean,
rinse with clean water and allow to dry before replac
ing on freezer.
If the condenser is not kept clean, loss of refrig-
eration efficiency will result.

4.8 PREVENTATIVE MAINTENANCE

It is recommended that a preventative maintenance sched-
ule be followed to keep the freezer clean and operating
properly. The following steps are suggested as a preven-
tative maintenance guide.
WARNING
Hazardous Voltage and Moving Parts
Never attempt to repair or perform any maintenance
on freezer until all main electrical power to freezer
has been disconnected. Failure to disconnect
electrical power before servicing may result in
serious injury or death.
The United States Department of Agriculture and the Food
and Drug Administration require that lubricants used in
food zones be certified for this use. Use lubricants only in
accordance with the manufacturer's instructions.
NOTE
NOTE
A.
Daily Checks
Check for any unusual noise or condition and repair
immediately.
B.
Monthly Checks
1. Check drive belts for wear and tighten belts if
necessary. (Refer to Section 4.5.)
2. Check the condenser for dirt. (Refer to Section
4.6).

4.9 EXTENDED STORAGE

Refer to the following steps for winterizing the freezer or
for storing the freezer over any long period of shutdown
time.
A.
Clean thoroughly with warm detergent all parts that
come in contact with mix. Rinse in clear water and
dry all parts. Do not sanitize.
Do not let cleaning solution stand in freezer barrel
or mix pump during the shutdown period.
B.
Remove, disassemble, and clean the front door,
auger shaft, and mix pump. Leave disassembled
during the shutdown period.
C.
Place plastic auger flights in a plastic bag with a
moist paper towel. This will prevent flights from
becoming brittle if exposed to dry air over an
extended period of time (over 30 days).
E.
Place the mix pump ON-OFF switches, Left and
Right Freezing Cylinder switches and the
Main Freezer Power switch in the OFF position.
F.
Disconnect from the source of electrical supply in
the building.

4.10 ERROR CODES

The following error condition codes will display on the
control panel when the freezer is experiencing a problem.
The error condition code directs you to the system location
of the malfunction.
ERROR CODE
01
02
03
04
05
06
07
08
09
Any error causing condition must be corrected, then the
power turned off, and back on before the freezer will return
to normal operation.
23
NOTE
MALFUNCTION
Program Board
High Torque Error
Extended Run Time Error
Clean Error
Freezing Cylinder Sensor
(not used on F431 models)
Drive Motor Current
Cab Sensor
High Pressure Cutout

Hide quick links: