Overview; Standard Display; Status Display - Wolf BM-Solar Installation And Operating Instructions Manual

Programming module
Table of Contents

Advertisement

Standard display

Status display

3061916_0611

Overview

Status display
Solar circuit pump
▪ In the top line of the standard display, the current solar cylinder
temperature is shown; the bottom line shows the current
collector temperature.
▪ In systems with two cylinders, the solar cylinder temperature of
cylinder 1 is shown.
▪ In systems with two collector arrays, the collector temperature
of collector array 1 is shown.
▪ The BUS symbol indicates that a BUS connection exists
between the programming module and the SM solar module.
The BUS connection is faulty if this symbol is not displayed.
This would prevent the solar module from being operated.
An arrow on the status display signals which output of the
connected solar module is currently active.
Status display
A1
A2
A3
-**
* Output assignment subject to configuration.
** An active output A4 is signalled by an arrow pointing downwards.
Display
Info
pushbutton
Solar cylinder temperature, cylinder 1
BUS symbol
Collector temperature, collector array 1
Status display, output A4
Status display, solar circuit pump 1 and
outputs A1-A3
In conjunction with
SM1 solar module SM2 solar module
Solar circuit pump Solar circuit pump 1
-
-
-
-
Rotary selector with
pushbutton function
ON / OFF
pushbutton
Output A1*
Output A2*
Output A3*
Output A4*
7